Menu
Your Cart
NOTICE: We have Fully discontinued physical walk-in customer service, RFQ, and LPO processing. Nerokas is now a FULLY DIGITAL ONLINE STORE, and our virtual assistant, Ginō AI, is here to help you navigate and checkout. Just ADD your Items to cart and type CHECKOUT on Ginō. Please note that corporate customers must register a corporate account to ensure proper Digital eTIMS/VAT processing.

UNI-T UT207B True RMS 1000A AC/DC Clamp Meter

UNI-T UT207B True RMS 1000A AC/DC Clamp Meter
UNI-T UT207B True RMS 1000A AC/DC Clamp Meter
New
UNI-T UT207B True RMS 1000A AC/DC Clamp Meter
UNI-T UT207B True RMS 1000A AC/DC Clamp Meter
UNI-T UT207B True RMS 1000A AC/DC Clamp Meter
KES 23,000.00
  • Stock: In Stock
  • Model: UNI-T UT207B True RMS 1000A AC
  • Weight: 465.00
  • Dimensions: 272.00 x 100.00 x 47.00
  • SKU: 4107

High-Performance Current Measurement and Precision Metrology

The UNI-T UT207B is an industrial-grade, heavy-duty True RMS digital clamp meter engineered to satisfy the demanding diagnostic requirements of commercial electricians, plant maintenance engineers, HVAC technicians, and electrical contractors. At the heart of its metrological performance is an advanced analog front-end that delivers True Root Mean Square (True RMS) calculations across complex, distorted, and non-sinusoidal AC waveforms up to 1000A and 1000V. Traditional averaging meters suffer from significant systematic errors when measuring distorted signals produced by modern non-linear loads, such as switch-mode power supplies, uninterruptible power supplies (UPS), and solid-state motor starters. The UT207B resolves these discrepancies by computing the true thermal equivalent of the alternating current waveform, maintaining exceptional accuracy across an operating bandwidth of 40Hz to 400Hz.

For direct current applications, the clamp meter incorporates precision Hall-effect sensors embedded within the 35mm jaw aperture. Measuring direct current up to 1000A DC with high linearity, the unit features a dedicated ZERO mode to cancel out residual magnetic flux, ambient geomagnetic interference, and thermal drift offsets before measurement. This makes it an indispensable tool for direct-current infrastructure, including solar photovoltaic (PV) combiner boxes, DC-coupled battery energy storage systems (BESS), telecommunications DC power distribution units (PDUs), and electric vehicle (EV) charging stations.

VFD Low-Pass Filtering and Ghost Voltage Suppression

Modern automated manufacturing facilities rely heavily on Variable Frequency Drives (VFDs) and Pulse Width Modulation (PWM) speed controllers. These drives introduce high-frequency switching noise, harmonics, and transient voltage spikes that standard multimeters fail to process correctly. The UNI-T UT207B addresses this industrial challenge with an active Low-Pass Filter (LPF) mode featuring an attenuation profile optimized to filter out high-frequency noise above 1kHz. When engaged, the LPF isolates the fundamental drive frequency, allowing maintenance technicians to measure the true operational voltage and current supplied to the motor without spurious carrier-frequency interference.

Equally critical for field safety and diagnostic accuracy is the Low Impedance (LoZ) measurement mode. In standard digital multimeters, an ultra-high input impedance of approximately 10 Megaohms can capture capacitive coupling between adjacent energized and de-energized cables within dense conduits, yielding phantom or ghost voltages that mislead technicians. The UT207B LoZ mode presents a low-impedance input circuit (approximately 300 kiloohms) across the test leads, safely dissipating low-energy phantom voltages to ground and definitively verifying whether a conductor is truly energized or merely carrying a benign induced charge.

Inrush Current Dynamics and High-Speed Sampling

Industrial three-phase motors, large inductive compressors, and power transformers exhibit massive starting current surges that can exceed full-load operating current by a factor of five to ten. Diagnosing nuisance tripping of thermal-magnetic circuit breakers and sizing motor-protection relays requires accurate measurement of these dynamic events. The UT207B incorporates a dedicated Inrush Current capture function with a high-speed integration window of 100 milliseconds. When the circuit detects a sudden current rise matching the trigger threshold, it freezes and displays the peak surge amplitude, eliminating guesswork and providing the necessary engineering data to optimize overload protection thresholds.

Comprehensive Multifunction Multimeter Capabilities

Beyond its primary clamp functionality, the UT207B houses a full-featured 6000-count digital multimeter. It provides AC/DC voltage measurement up to 1000V with overvoltage protection, resistance measurement up to 60 Megaohms, capacitance testing up to 60 Millifarads (60,000 microfarads), and frequency evaluation spanning 10Hz to 1 Megaohm. For thermal monitoring, the instrument integrates an internal cold-junction compensated temperature sensor that connects with external Type-K thermocouples to measure thermal parameters from -40 degrees Celsius to 1000 degrees Celsius (-40 degrees Fahrenheit to 1832 degrees Fahrenheit), streamlining the diagnosis of bearing friction, overheated busbars, and thermodynamic subcooling or superheat in refrigeration circuits.

Interface, Safety Architecture, and Terminal Configuration

The device is built to adhere to strict CAT III 1000V and CAT IV 600V safety standards, featuring double-insulated construction, internal high-energy ceramic blast fuses, and transient surge suppression capable of withstanding industrial transients up to 8kV. The physical interface provides a large dual-line LCD display with high-contrast backlighting, a bar-graph display for rapid trend spotting, and an integrated high-lumen worklight illuminating dark switchgear cabinets.

The test lead terminal interface (pinout) is configured through standardized shrouded 4mm safety banana jacks located at the base of the meter:

1. COM Terminal (Return/Negative Jack): The universal ground reference and low-potential input terminal. This jack serves as the common return connection for all voltage measurements, resistance tracing, diode forward-voltage testing, audible continuity, capacitance evaluations, frequency monitoring, and the negative cold-leg of Type-K thermocouple adapters.

2. INPUT Terminal (Positive Jack for Volts, Ohms, Hertz, Capacitance, Diode, and Temperature): High-potential positive measurement terminal. Coupled internally with high-voltage divider networks and positive-temperature-coefficient (PTC) thermistors, this terminal accepts positive polarity inputs for measuring AC/DC voltage up to 1000V, low-pass filtered voltage signals, LoZ impedance sensing, high-precision resistance, diode junction profiling up to 3.0V, capacitance up to 60mF, and thermocouple positive signals.

3. Transformer / Hall-Effect Induction Jaw (Contactless Amperage Pinout): A 35mm toroidal clamp opening lined with high-permeability magnetic silicon steel laminations and dual differential Hall-effect sensors. Designed for single-conductor pass-through measurement, it registers AC magnetic flux via magnetic induction and DC flux via the Hall voltage effect across the 0A to 1000A scale without metallic contact.

4. NCV Sensor Array (Antenna Interface): An internal capacitive antenna located in the tip of the moving clamp jaw. It senses ambient electric fields generated by AC line voltages between 80V and 1000V, alerting the user through a multi-stage visual LED indicator and an audible piezo beeper.

Eight Industrial Application Use-Cases

1. Industrial Motor Inrush and Full-Load Amperage (FLA) Profiling: Industrial technicians use the 100ms inrush mode to capture startup draw during motor line-starting, pinpointing mechanical binding, worn bearings, or miscalculated circuit breaker trip curves in manufacturing plants.

2. Variable Frequency Drive (VFD) Output Diagnostics: Utilizing the hardware Low-Pass Filter (LPF), technicians eliminate PWM switching frequencies to accurately measure the fundamental drive voltage and current delivered to synchronous and asynchronous motors.

3. Commercial Solar Photovoltaic (PV) Array DC String Testing: The clamp measures DC current up to 1000A across multiple parallel solar combiner boxes and central inverter DC busbars, detecting degraded solar strings, bypass diode failures, and mismatched panel arrays.

4. Battery Energy Storage Systems (BESS) and UPS Maintenance: Engineers monitor DC charge and discharge rates in high-capacity utility-scale battery racks, utilizing the zeroing feature to cancel residual offset and verify cell bank equilibrium.

5. Eliminating Ghost Voltage in De-Energized Feeder Lines: Electricians deploy LoZ mode in multi-conductor raceways to dissipate capacitively coupled induced voltages, confirming complete system de-energization before executing lock-out/tag-out (LOTO) protocols.

6. HVAC/R Compressor Run/Start Capacitor and Phase Load Assessment: Technicians use the 60mF capacitance range to evaluate motor run capacitors, verify dual-stage compressor current balance, and capture Type-K temperature metrics on liquid and suction lines simultaneously.

7. Three-Phase Electrical Distribution Switchgear Load Balancing: Facility managers clamp the individual phase feeders (L1, L2, L3) and the neutral conductor to check phase balance, identify high neutral currents driven by third-harmonic distortion, and avert transformer saturation.

8. Electrical Substation Grounding and Industrial Control Panel Diagnostics: Technicians utilize the high-precision resistance, continuity, and non-contact voltage (NCV) detection circuits to rapidly trace terminal block integrity, verify ground bonding continuity, and inspect dense 24V/120V automation enclosures without disrupting live operations.


Specifications of UT200 Series 1000A True RMS Digital Clamp Meters

Specifications

Range

UT205E

UT206B

UT207B

UT208B

AC current (A)

1000A

±(2%+5)

±(2%+5)

±(2%+5)

±(2%+5)

DC current (A)

1000A

±(2%+5)

±(2%+5)

AC current frequency response

50Hz~60Hz

50Hz~60Hz

40Hz~400Hz

40Hz~400Hz

Inrush current (A)

1000A

±(10%+10)

±(10%+10)

±(10%+10)

AC voltage (V)

1000V

±(1.2%+3)

±(1.2%+3)

±(1.2%+3)

±(1.2%+3)

DC voltage (V)

1000V

±(0.5%+5)

±(0.5%+5)

±(0.5%+5)

±(0.5%+5)

Low pas filter (LPF ACV)

1000V

±(2%+5)

±(2%+5)

±(2%+5)

AC voltage frequency response

40Hz~400Hz

40Hz~400Hz

40Hz~400Hz

40Hz~400Hz

LoZ ACV

1000V

±(2%+5)

±(2%+5)

±(2%+5)

Resistance (Ω)

60MΩ

±(1%+2)

±(1%+2)

±(1%+2)

±(1%+2)

Capacitance (F)

60mF

±(4%+5)

Tags: UNI-T , UT207B , Clamp Meter , True RMS , 1000A , AC/DC Current , Multimeter , Inrush Current , Test Tools