High-Precision Industrial Power Diagnostics
Engineered for heavy industrial electricians, HVAC technicians, and electrical engineers, this high-performance digital clamp meter provides comprehensive diagnostic capabilities for complex electrical systems. Featuring a robust 6000-count backlit display, the meter delivers precise True RMS measurements up to 1000A AC and DC directly through its high-durability jaw. Whether troubleshooting commercial service panels, industrial switchgear, or solar power generation arrays, this tool ensures accurate current and voltage readings even on distorted or non-sinusoidal waveforms.
Advanced Motor Drive and Variable Frequency Diagnostics
Modern electrical environments are filled with electrical noise and parasitic voltage spikes. This clamp meter integrates a Low Pass Filter (LPF) mode specifically calibrated to attenuate high-frequency harmonics generated by Variable Frequency Drives (VFDs) and inverter systems, allowing precise measurement of the fundamental frequency output voltage. To prevent misleading readings caused by stray capacitive coupling, the Low Impedance (LoZ) voltage mode eliminates ghost voltage ghosting on de-energized conductors. Furthermore, the integrated Inrush Current mode captures peak transient starting currents of electric motors and inductive loads during motor boot-up sequence with microsecond-level accuracy.
Extended Measurement Range and High Capacitance Testing
Beyond standard current clamp limits, this meter supports high-precision thermal diagnostics via K-type temperature sensors with 0.1 degree centigrade resolution. For extremely wide conductors or tightly packed busbars, the meter seamlessly pairs with an optional flexible current probe to expand its AC current measurement range up to an impressive 3000A. The unit also features an exceptional 60mF (60,000 microfarad) capacitance measurement capability, making it an essential diagnostic tool for testing oversized motor start and run capacitors.
Integrated Safety and Non-Contact Sensing
Built to meet rigorous industrial safety standards, the meter features an advanced Non-Contact Voltage (NCV) detection function. Incorporating a multi-segment visual LED indicator alongside responsive audible alerts, operators can quickly identify energized lines without physical contact. Coupled with rugged ergonomic housing, high-durability lead ports, and overload protection across all measurement ranges, this instrument is built to withstand demanding industrial job site conditions.
Specifications of UT200 Series 1000A True RMS Digital
Clamp Meters
Specifications | Range | UT205E | UT206B | UT207B | UT208B |
AC current (A) | 1000A | ±(2%+5) | ±(2%+5) | ±(2%+5) | ±(2%+5) |
DC current (A) | 1000A | ±(2%+5) | ±(2%+5) | ||
AC current frequency response | 50Hz~60Hz | 50Hz~60Hz | 40Hz~400Hz | 40Hz~400Hz | |
Inrush current (A) | 1000A | ±(10%+10) | ±(10%+10) | ±(10%+10) | |
AC voltage (V) | 1000V | ±(1.2%+3) | ±(1.2%+3) | ±(1.2%+3) | ±(1.2%+3) |
DC voltage (V) | 1000V | ±(0.5%+5) | ±(0.5%+5) | ±(0.5%+5) | ±(0.5%+5) |
Low pas filter (LPF ACV) | 1000V | ±(2%+5) | ±(2%+5) | ±(2%+5) | |
AC voltage frequency response | 40Hz~400Hz | 40Hz~400Hz | 40Hz~400Hz | 40Hz~400Hz | |
LoZ ACV | 1000V | ±(2%+5) | ±(2%+5) | ±(2%+5) | |
Resistance (Ω) | 60MΩ | ±(1%+2) | ±(1%+2) | ±(1%+2) | ±(1%+2) |
Capacitance (F) | 60mF | ±(4%+5) | ±(4%+5) | ±(4%+5) | ±(4%+5) |
Temperature | -40℃~1000℃ | ||||